Digital I/O expansion for the Safety-M basis modules.
The module is connected to the basic module via a backplane bus connector that snaps onto the standard top-hat rail.
The expansion module has 2 safe I/O optionally configurable as inputs or outputs, 12 safe inputs, 2 messaging outputs as well as 4 safe relay outputs.
Type
EM4
Dimensions
99x114,5x90 mm
Mounting
snap-on mounting on standard head rail
Protection
IP 52
Temperature
0...+50°C
Power supply
24 VDC
Max. number of extension modules
0
Output data
Interface for extension modules
T-bus connector for top hat rail mount
Safe digital input lines
12 incl. 8 OSSD
Safe digital output lines
2
Safe relay outputs
4
Standard output lines
2
Pulse output lines
2
Type of connection
pluggable terminals
Digital I/O extension for the Safety-M basic modules.
This module is connected to the basic module via the backplane bus connector to snap on the standard rail.
The extension module offers 2 safe I/O configurable either as inputs or outputs, 12 safe inputs, 2 signal outputs and 8 relay outputs.
Thông tin liên hệ
Phone : (08) 3517.4923 Fax: (08) 3517.4924